FabRICATOR® Lyophilized

Lyophilized enzyme for below hinge digestion of IgG

Available Products

FabRICATOR (IdeS) is an IgG-specific cysteine protease that digests antibodies at a single amino acid site below the hinge, generating homogenous F(ab’)2 and Fc fragments.

FabRICATOR Lyophilized is available as a lyophilized powder in 2000 (A0-FR1-020), 5000 (A0-FR1-050) and 5 x 5000 (A0-FR1-250, value pack) unit vials for digestion of 2, 5 and 5 x 5 mg IgG respectively, and in 8 x 100 unit strip wells and 96 x 100 unit well plates for digestion of 8 x 100 µg and 96 x 100 µg IgG respectively.

Why FabRICATOR® Lyophilized?

  • Flexible format for method development
  • Possible to combine enzymes for improved efficiency
  • Amenable to automated workflows
  • Ready to use – just add water!

Available Products

  • FabRICATOR® Lyophilized 2000 units

    Lyophilized enzyme for below hinge digestion of 2 mg IgG

    A0-FR1-020

    $979.00

    • FabRICATOR® Lyophilized 5000 units

      Lyophilized enzyme for below hinge digestion of 5 mg IgG

      A0-FR1-050

      $1,160.00

      • FabRICATOR® Lyophilized 5 x 5000 units

        Lyophilized enzyme for below hinge digestion of 5 x 5 mg IgG

        A0-FR1-250

        $5,035.00

        • FabRICATOR® Lyophilized 8 x 100 units

          Lyophilized enzyme for below hinge digestion of 8 x 100 𝜇g IgG

          A0-FR1-008

          $569.00

          • FabRICATOR® Lyophilized 96 x 100 units

            Lyophilized enzyme for below hinge digestion of 96 x 100 𝜇g IgG

            A0-FR1-096

            $3,121.00

            For information on how to order, visit Place an Order or contact us directly at order@genovis.com.

            Product Information

            Unit Defintion

            One unit digests ≥ 95% of 1µg human IgG when incubated in 10 mM sodium phosphate, 137 mM NaCl, 2.7 mM KCl pH 7.4 at 37°C for 30 min.

            Buffers

            The buffers below have been tested for compatibility with FabRICATOR digestion at different pH. Note that the FabRICATOR enzyme is irreversibly inactivated below pH 5.0. Digestion above pH 8.0 requires prolonged/optimized conditions.

            • Phosphate buffer saline (PBS) 6.0 – 8.0
            • Tris buffer 7.0 – 8.0
            • MES buffer 5.5 – 6.5
            • HEPES buffer 7.0 – 8.0
            • Ammonium bicarbonate buffer 6.0 – 7.0
            • Sodium acetate buffer 6.0

            Content and Storage

            FabRICATOR Lyophilized is reconstituted by addition of water. No preservatives added. After reconstitution, the enzyme is stable for 1 month at +4-8°C. The product is shipped at ambient temperature, and should be stored at -20°C upon arrival.

            Resources

            Applications

            Performance Activity

            FAQ and Support

            Yes, FabRICATOR should be able to digest a Fc fusion protein as long as you have not fused the protein too close to the cleavage site. FabRICATOR digests human IgG just below the hinge (…CPAPELLG / GPSVF…), leaving the hinge on the fusion-part.

            We have tested 4-6 M GuHCl which the enzyme does not withstand without significant decrease of activity. SDS have not been evaluated but 0.1% RapiGest from waters have negative influence on activity. Taken together the enzyme does not well tolerate denaturing agents although we have not tested this in more detailed studies.

            We have no stability data for storage at -20°C or -70°C. However, we have customer reporting that they successfully stored reconstituted FabRICATOR at -20°C or -70°C for a couple of months. Genovis cannot guarantee the activity of the enzyme, but these storage conditions might be OK depending on the intended application.

            It is possible to use FabRICATOR with low concentrations of IgG. Low concentrations of IgG will lead to decreased reaction rate, so for concentrations below 0.5mg/mL it is therefore recommended to increase the amount of added enzyme and/or increase the incubation time. There is no risk of over-digestion and the incubation time can be prolonged to O/N if necessary.

            If we assume that the antibody concentration in serum is 15 mg/ml you would have to add 10-15 000 units to a sample of 1 ml serum. In 50 µl serum you would have to add 500 – 750 units of FabRICATOR.