FabRICATOR® Z Fab2 Kit

Immobilized enzyme and affinity resin for below hinge digestion of mouse IgG2a and IgG3 and purification of fragments

Available Products

FabRICATOR Z (IdeZ) is a cysteine protease that digests mouse IgG2a and IgG3 at a specific site below the hinge, generating a homogenous pool of F(ab’)2 and Fc fragments after a two-hour incubation.

FabRICATOR Z Fab2 Kit consists of spin columns of FabRICATOR Z Immobilized for antibody digestion, and spin columns of CaptureSelect™* Fc resin for purification of fragments. One FabRICATOR Z spin column contains sufficient FabRICATOR Z-coupled agarose beads to process 0.5 mg mouse IgG2a and IgG3.

Why FabRICATOR® Z Fab2 Kit?

  • Purification of homogenous F(ab’)2 fragments from mouse IgG2a and IgG3
  • Fast – pure fragments in under two hours
  • Reliable workflow for preparative applications

Available Products

  • FabRICATOR® Z Fab2 Kit Microspin 0.5 mg

    Immobilized enzyme and affinity resin for below hinge digestion of 0.5 mg mouse IgG2a and IgG3 and purification of fragments

    A2-FZ2-005

    545.00

    • FabRICATOR® Z Fab2 Kit Microspin 5 x 0.5 mg

      Immobilized enzyme and affinity resin for below hinge digestion of 5 x 0.5 mg mouse IgG2a and IgG3 and purification of fragments

      A2-FZ2-025

      1,450.00

      For information on how to order, visit Place an Order or contact us directly at order@genovis.com.

      Product Information

      Activity

      One spin column contains sufficient FabRICATOR Z-coupled agarose beads to digest 0.5 mg mouse IgG2a or IgG3.

      Content and Storage

      The FabRICATOR Z Immobilized spin columns and CaptureSelect™* spin columns are supplied in 20% ethanol, shipped cold, and should be stored at +4-8°C upon arrival. Do not freeze the products!

      Resources

      FAQ and Support

      We can only guarantee optimal digestion for one-time use. We do not have a cleaning or regeneration protocol to provide. However, depending on the antibody and the following application the column can be reused. We do not recommend using with different antibodies due to the risk for contamination of carry-over from previous sample. If column reuse is desired store the column in 10-20% ethanol at +4-8°C.

      It is possible to elute the Fc fragments from the CaptureSelect column using a low pH buffer, for example a 0.1M Glycine buffer pH=3.0. The pH must immediately after elution be adjusted to neutral pH by adding 0.1x elution volume of 1M Tris pH=8.0.